VOPV Combiner Series

VOPV600-1/1 Solar PV Combiner Box

1-input, 1-output 600 V DC solar PV combiner box for protected wall-mounted DC distribution.

600 V DCMaximum system voltage
1/1Input / output arrangement
32 AMaximum output current
IP65Protection degree
Technical data
VOPV600-1/1 600V one-input one-output solar PV combiner box01 / PRODUCT VIEW

VOPV600-1/1 combines 1 photovoltaic input circuit into 1 protected output. The wall-mounted assembly integrates string fuses, Type 2 DC surge protection and VOD1 load-break isolation in an IP65 enclosure.

02 / TECHNICAL DATA

VOPV600-1/1 technical data

Use these values for initial selection. Confirm string voltage, corrected current, fuse coordination, internal circuit arrangement and controlled documentation before ordering.

Electrical, protection and enclosure specifications

Maximum system voltage600 V DC
Input / output arrangement1/1
Maximum output current32 A
Protection degreeIP65
Enclosure modelVOAT-9
Enclosure dimensions (W × H × D)218 × 200 × 100 mm
Enclosure materialPC / ABS
Impact resistanceIK10
String fuse holders2 × VOPV-32
Fuse links2 × 10 × 38 mm, 15 A

Enclosure dimensions

Dimension drawing

Request the current dimension drawing for this model.

03 / PRODUCT SELECTION

Configure VOPV600-1/1

System voltage — Fixed for this model
Circuit arrangement — Input / output
Required documents — Select for project review
04 / APPLICATIONS

Applications for VOPV600-1/1

01

PV string protection

Protect 1 photovoltaic input circuit with dedicated positive and negative fuse links.

02

Surge protection and isolation

Integrate Type 2 DC surge protection and load-break isolation ahead of the inverter or DC distribution equipment.

03

Outdoor wall mounting

Use the IP65 PC/ABS enclosure for protected wall-mounted photovoltaic installations.

05 / RESOURCES

VOPV600-1/1 controlled documents

Request documents matched to the final circuit arrangement and destination market.

What is the circuit arrangement of VOPV600-1/1?

VOPV600-1/1 has 1 photovoltaic input and 1 protected output.

What is the maximum voltage of VOPV600-1/1?

The listed maximum system voltage is 600 V DC. Confirm the corrected cold-weather array open-circuit voltage before selection.

Which protection devices are included?

The listed bill of materials includes 2 VOPV-32 fuse holders with 15A fuse links, 1 Type 2 DC surge arrester and 1 VOD1-63 switch disconnector.

Can the internal components be changed?

Project-specific component and enclosure requirements can be reviewed. The final bill of materials and order code must be confirmed in the quotation.

READY FOR SELECTION?

Confirm VOPV600-1/1 for your application.