VOPV Combiner Series

VOPV1000-2/1 Solar PV Combiner Box

2-input, 1-output 1000 V DC solar PV combiner box for protected wall-mounted DC distribution.

1000 V DCMaximum system voltage
2/1Input / output arrangement
45 AMaximum output current
IP65Protection degree
Technical data
VOPV1000-2/2 1000V two-input two-output solar PV combiner box01 / PRODUCT VIEW

VOPV1000-2/1 combines 2 photovoltaic input circuits into 1 protected output. The wall-mounted assembly integrates string fuses, Type 2 DC surge protection and VOD1 load-break isolation in an IP65 enclosure.

02 / TECHNICAL DATA

VOPV1000-2/1 technical data

Use these values for initial selection. Confirm string voltage, corrected current, fuse coordination, internal circuit arrangement and controlled documentation before ordering.

Electrical, protection and enclosure specifications

Maximum system voltage1000 V DC
Input / output arrangement2/1
Maximum output current45 A
Protection degreeIP65
Enclosure modelVOAT-13
Enclosure dimensions (W × H × D)298 × 230 × 120 mm
Enclosure materialPC / ABS
Impact resistanceIK10
String fuse holders4 × VOPV-32
Fuse links4 × 10 × 38 mm, 15 A

Enclosure dimensions

Dimension drawing

Request the current dimension drawing for this model.

03 / PRODUCT SELECTION

Configure VOPV1000-2/1

System voltage — Fixed for this model
Circuit arrangement — Input / output
Required documents — Select for project review
04 / APPLICATIONS

Applications for VOPV1000-2/1

01

PV string protection

Protect 2 photovoltaic input circuits with dedicated positive and negative fuse links.

02

Surge protection and isolation

Integrate Type 2 DC surge protection and load-break isolation ahead of the inverter or DC distribution equipment.

03

Outdoor wall mounting

Use the IP65 PC/ABS enclosure for protected wall-mounted photovoltaic installations.

05 / RESOURCES

VOPV1000-2/1 controlled documents

Request documents matched to the final circuit arrangement and destination market.

What is the circuit arrangement of VOPV1000-2/1?

VOPV1000-2/1 has 2 photovoltaic inputs and 1 protected output.

What is the maximum voltage of VOPV1000-2/1?

The listed maximum system voltage is 1000 V DC. Confirm the corrected cold-weather array open-circuit voltage before selection.

Which protection devices are included?

The listed bill of materials includes 4 VOPV-32 fuse holders with 15A fuse links, 1 Type 2 DC surge arrester and 1 VOD1-63 switch disconnector.

Can the internal components be changed?

Project-specific component and enclosure requirements can be reviewed. The final bill of materials and order code must be confirmed in the quotation.

READY FOR SELECTION?

Confirm VOPV1000-2/1 for your application.